5.26 -34 : Authentication
5.2
" IGN On (Engine Start) after H/L (SOL) is unlocked "
When ***** SW On is detected, if FOB is detected within the communication range, SOL is unlocked and the engine start(EV READY) permission is sent to
FI-ECU(PCU) by IGN On
5.3
H/L(SOL) UNLOCK (IGN ON is not detected)
After ***** SW ON is detected, if FOB is detected within the communication range, SOL is unlocked.
If IGN ON is not detected within 20s, output stops and WINKER, BUZZER output is performed.
if MAIN SW ON is detected when SOL is Locked, SMART IND and IMOID output is performed and ***** SW input is not accepted.
5.4
H/L (SOL) LOCK from IGN OFF
The user walks away from the vehicle.
When IGN OFF is detected, the cyclic SMART communication starts. If the FOB is outside the communication range , SOL is locked.
5.5
H/L (SOL) LOCK from IGN OFF (within the communication range)
the user is in the communication range
When IGN off is detected, the cyclic SMART communication starts. When the specific time elapsed, SOL is locked.
If there is no FOB immediately after the Main SW is turned off, BUZZER and WINKER are output, and SOL is Locked
5.6
H/L (SOL) LOCK from IGN OFF (***** SW ON)
H/L is Locked by the user
When IGN OFF is detected, the cyclic SMART communication starts. IF ***** SW ON is detected, SOL is Locked
5.7
FOB missing detection indication
When IGN ON and engine Start are detected , the cyclic SMART Communication starts. If the FOB is out of the communication range SMART IND blinks.
Criteria: SMART communication is failed 5 times in a row.
(1 SMART communication for 1 FOB = 10 retry.
5 continuous SMART communication failure=5 Times* 10 retry = 50 retry failure)
After FOB missing is detected , if the engine stops , BUZZER starts. if the engine starts after BUZZER starts, BUZZER stops.
if the engine stops after the FOB fall is confirmed , a buzzer sounds to notify the rider.
if the smart Communication during the FOB fall notification becomes Ok after the start of the buzzer sound, the buzzer sound and FOb fall detection are stopped.
if the engine stops before FOB missing is detected, FOB missing detection stops.
if the engine starts after FOB missing detection stopped, FOB missing detection restarts.
5.8
FOB missing indication cancel
After the FOB missing is detected, SMART communication is recovered.
If SMART communication is recovered While FOB missing is indicated , SMART IND blinking stops.
5.9
IGN ON indication by IGN OFF detection while FOB missing is detected
While FOB missing is detected , if IGN OFF is detected, SOL is unlocked for the specific time, and the IND blinks with buzzer sound to indicate the user to turn IGN ON again.
Under the following conditions, BUZZER/WINKER stops and sol is unlocked
***** SW is Pressed and held for 2s or longer
5.10 : open Opener BOX
5.11
Low FOB Battery indication
only if the FOB which has unlocked the H/L has low battery voltage, SMART IND blinks 5times after MAIN SW ON.
5.12
Alarm State Transition
5.13
Alarm Performance Specification 1
5.14
Alarm performance Specification 2
5.15
Alarm performance Specification 3
5.16
Alarm Set Control 1
5.17
Alarm Set Control 2
5-18
Answer Back
During Main SW OFF , if the specific keyless signal (A/B) is received, WINKLER, BUZZER, FACE LED outputs are performed. IF the recived keyless signal is BUZ sound OFF (A/B without the buzzer), Buzzer output is not performed.
Buzzer has several pattern of sound/volume which can be selected by the user.
During WINKER/BUZZER output,keyless Signals (A/B with/Without Buzzer) are ignored.
During MAIN SW OFF, keyless signals are checked periodically with the low power consumption mode.
10 days after the MAIN SW OFF or BATT ON (with no MAIN SW On) the state shifts to NOT FUNCTIONING.
if ANSWER BACK is performed the state shift to NON FUNCTIONING 10 days after ANSWER bACK was performed.
During NOT FUNCTIONING keyless signal is not recived. The State recovers by MAIN SW ON.
When SOL Locked again when the smart authnatication is performed within the 60s after the Answerback is performed, FACE LED turns off if 60s have not elapsed after ANSWER BACK was performed.
ANSWER BACK is performed even when the SMART authentication is completed and MAIN SW OFF . When SOl Locaked FACE LED turns OFF (60s Lighting does not continue)
5.19
ANSWER BCAK BUZZER stop
While ANSWER BCAK is performed , if ***** SW ON is detected, SMART communication starts.
If FOB is detected within the communication range, Answer output Stops.
5.20
ANSWER BACK sound Volume changes
In the AUTHENTICATION COMPLETE mode, if ***** SW ON is detected for 4s or longer the state shifts to the setting change mode.
During the setting change mode, the sound volume setting can be changed by the ANSWER BCAK RF signal and the ***** SW operation.
The Sound volume is changed in the order of 'MAX'-> 'Mid'-> 'Min' by receiving keyless signals, starting from the sound volume currently set.
The BUZZER output during the sound Volume settings changes use the sound type currently set.
The setting change is implemented when the normal keyless signal is recived
The sound volume settings does not change by the keyless signal during the BUZZER output.
writing in the non-volatile memory is performed at the same time when the BUZZER output is performed after normal signal is recived, Default sound volume setting is MAX
5.21
ANSWER BACK sound type change
In the AUTHENTICATION COMPLETE mode, if ***** SW ON is detected for 4s or longer the state shifts to the setting change mode.
During the setting change mode, the sound type setting can be changed by the answer back RF Signals and the ***** SW operation.
The Sound type is changed in the order of 1->2->3 by receiving keyless signals starting from the sound type current set.
The setting change is implemented when the normal keyless signal is received.
The Sound type setting does not change by the keyless signals during the BUZZER output.
Writing in the non-volatile memory is performed at the same time when the Buzzer output is performed after a normal signal is recived.
default sound type setting is 2
5.22
Setting mode (Without normal)
If the MAIN SW is turned ON during the setting mode (including When the SMART IND is blinking due to timeout ) exit the setting mode , immediately output SMART IND and IMOID and perform IMOBI authentication
5.25
If ***** SW ON continues for 4s or longer and FOB IF Input , the IND indicates the failure to the user